Biomechanical effects of osteoplasty with or without Kirschner wire augmentation on long bone diaphyses undergoing bending stress: implications for percutaneous imaging-guided consolidation in cancer patients

骨成形术(伴或不伴克氏针加固)对承受弯曲应力的长骨干的生物力学影响:对癌症患者经皮影像引导下骨整合的启示

阅读:1

Abstract

BACKGROUND: Osteoplasty has been discouraged in long bones. However, despite a substantial lack of pre-clinical biomechanical tests, multiple clinical studies have implemented a wide range of techniques to optimise long bone osteoplasty. The aim of the present study is to evaluate the biomechanical properties of osteoplasty alone and in combination with Kirschner wires (K-wires) in a cadaveric human diaphyseal model undergoing 3-point bending stress. METHODS: Thirty unpaired human cadaveric hemi-tibia specimens were randomly assigned to receive no consolidation (group 1, n = 10), osteoplasty alone (group 2, n = 10), or K-wires augmented osteoplasty (group 3, n = 10). Specimens were tested on a dedicated servo-hydraulic machine using a 3-point bending test. Fracture load was calculated for each specimen; two-sample Wilcoxon rank-sum tests were used to assess differences between groups. RESULTS: Median volume of polymethyl methacrylate injected was 18 mL for group 2 (25th-50th percentile 15-21 mL) and 19 mL for group 3 (25th-50th percentile 17-21). There were no significant differences in fracture load between groups 1 and 2 (z = - 0.793; p = 0.430), between groups 1 and 3 (z = - 0.944; p = 0.347), and between groups 2 and 3 (z = - 0.454; p = 0.650). Fractures through the cement occurred in 4 of 30 cases (13.3%); there were no K-wires fractures. CONCLUSIONS: Osteoplasty with or without K-wires augmentation does not improve the resistance of diaphyseal bone to bending stresses.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。