Hysteretic device characteristics indicate cardiac contractile state for guiding mechanical circulatory support device use

滞后装置特性可指示心脏收缩状态,从而指导机械循环支持装置的使用。

阅读:1

Abstract

BACKGROUND: Acute heart failure and cardiogenic shock remain highly morbid conditions despite prompt medical therapy in critical care settings. Mechanical circulatory support (MCS) is a promising therapy for these patients, yet remains managed with open-loop control. Continuous measure of cardiac function would support and optimize MCS deployment and weaning. The nature of indwelling MCS provides a platform for attaining this information. This study investigates how hysteresis modeling derived from MCS device signals can be used to assess contractility changes to provide continuous indication of changing cardiac state. Load-dependent MCS devices vary their operation with cardiac state to yield a device-heart hysteretic interaction. Predicting and examining this hysteric relation provides insight into cardiac state and can be separated by cardiac cycle phases. Here, we demonstrate this by predicting hysteresis and using the systolic portion of the hysteresis loop to estimate changes in native contractility. This study quantified this measurement as the enclosed area of the systolic portion of the hysteresis loop and correlated it with other widely accepted contractility metrics in animal studies (n = 4) using acute interventions that alter inotropy, including a heart failure model. Clinical validation was performed in patients (n = 8) undergoing Impella support. RESULTS: Hysteresis is well estimated from device signals alone (r = 0.92, limits of agreement: - 0.18 to 0.18). Quantified systolic area was well correlated in animal studies with end-systolic pressure-volume relationship (r = 0.84), preload recruitable stroke work index (r = 0.77), and maximum slope of left ventricular pressure (dP/dt(max)) (r = 0.95) across a range of inotropic conditions. Comparable results were seen in patients with dP/dt(max) (r = 0.88). Diagnostic capability from ROC analysis yielded AUC measurements of 0.92 and 0.90 in animal and patients, respectively. CONCLUSIONS: Mechanical circulatory support hysteretic behavior can be well modeled using device signals and used to estimate contractility changes. Contractility estimate is correlated with other accepted metrics, captures temporal trends that elucidate changing cardiac state, and is able to accurately indicate changes in inotropy. Inherently available during MCS deployment, this measure will guide titration and inform need for further intervention.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。