Development and validation of a high-sensitivity assay for measuring p217+tau in plasma

开发并验证一种用于测量血浆中 p217+tau 的高灵敏度检测方法

阅读:9
作者:Gallen Triana-Baltzer, Setareh Moughadam, Randy Slemmon, Kristof Van Kolen, Clara Theunis, Marc Mercken, Hartmuth C Kolb

Discussion

The assay described here exhibits good technical performance and shows potential as a highly accurate peripheral biomarker for A or T status in AD and cognitively normal subjects.

Methods

Qualification of a Simoa plasma p217+tau assay was performed, followed by clinical utility evaluation in a cohort of 227 subjects with broad A and T spectrum.

Results

The p217+tau plasma assay was accurate, precise, dilution linear, and highly sensitive. All measured samples were within linear range of the assay, presented higher concentration in AD versus healthy controls (P < .0001), and plasma and cerebrospinal fluid levels correlated (r2 = 0.35). The plasma p217+tau results were predictive of central T and A status (area under the curve = 0.90 and 0.90, respectively) with low false +/- rates.