Biodistribution, radiation dosimetry and scouting of 90Y-ibritumomab tiuxetan therapy in patients with relapsed B-cell non-Hodgkin's lymphoma using 89Zr-ibritumomab tiuxetan and PET

利用 89Zr-ibritumomab tiuxetan 和 PET 对 90Y-ibritumomab tiuxetan 治疗复发性 B 细胞非霍奇金淋巴瘤患者进行生物分布、辐射剂量测定和预处理。

阅读:2

Abstract

PURPOSE: Positron emission tomography (PET) with (89)Zr-ibritumomab tiuxetan can be used to monitor biodistribution of (90)Y-ibritumomab tiuxetan as shown in mice. The aim of this study was to assess biodistribution and radiation dosimetry of (90)Y-ibritumomab tiuxetan in humans on the basis of (89)Zr-ibritumomab tiuxetan imaging, to evaluate whether co-injection of a therapeutic amount of (90)Y-ibritumomab tiuxetan influences biodistribution of (89)Zr-ibritumomab tiuxetan and whether pre-therapy scout scans with (89)Zr-ibritumomab tiuxetan can be used to predict biodistribution of (90)Y-ibritumomab tiuxetan and the dose-limiting organ during therapy. METHODS: Seven patients with relapsed B-cell non-Hodgkin's lymphoma scheduled for autologous stem cell transplantation underwent PET scans at 1, 72 and 144 h after injection of ~70 MBq (89)Zr-ibritumomab tiuxetan and again 2 weeks later after co-injection of 15 MBq/kg or 30 MBq/kg (90)Y-ibritumomab tiuxetan. Volumes of interest were drawn over liver, kidneys, lungs, spleen and tumours. Ibritumomab tiuxetan organ absorbed doses were calculated using OLINDA. Red marrow dosimetry was based on blood samples. Absorbed doses to tumours were calculated using exponential fits to the measured data. RESULTS: The highest (90)Y absorbed dose was observed in liver (3.2 ± 1.8 mGy/MBq) and spleen (2.9 ± 0.7 mGy/MBq) followed by kidneys and lungs. The red marrow dose was 0.52 ± 0.04 mGy/MBq, and the effective dose was 0.87 ± 0.14 mSv/MBq. Tumour absorbed doses ranged from 8.6 to 28.6 mGy/MBq. Correlation between predicted pre-therapy and therapy organ absorbed doses as based on (89)Zr-ibritumomab tiuxetan images was high (Pearson correlation coefficient r = 0.97). No significant difference between pre-therapy and therapy tumour absorbed doses was found, but correlation was lower (r = 0.75). CONCLUSION: Biodistribution of (89)Zr-ibritumomab tiuxetan is not influenced by simultaneous therapy with (90)Y-ibritumomab tiuxetan, and (89)Zr-ibritumomab tiuxetan scout scans can thus be used to predict biodistribution and dose-limiting organ during therapy. Absorbed doses to spleen were lower than those previously estimated using (111)In-ibritumomab tiuxetan. The dose-limiting organ in patients undergoing stem cell transplantation is the liver.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。