[Factors Contributing to Inferior Vena Cava Filter Removal Failure using Advanced Techniques: A Single-Center Study]

[采用先进技术进行下腔静脉滤器取出失败的影响因素:一项单中心研究]

阅读:1

Abstract

PURPOSE: To investigate the factors contributing to inferior vena cava (IVC) filter removal failure by comparing successful and failed cases using advanced techniques. MATERIALS AND METHODS: IVC filter removal was attempted in 331 patients. Of the 29 patients in whom IVC filter removal failed using a simple technique, the IVC filter was successfully removed using an advanced technique in 18 patients and failure was noted in 11 patients. Age, sex, filter type, indwelling period, IVC diameter, tilting angle between the IVC and the filter, IVC wall penetration of the filter strut, and whether the filter was embedded or endothelialized within the IVC wall were compared in each group. RESULTS: Overall, there were 13 men (72%) in the success group and 3 men (27%) in the failure group; more women were present in the failure group (p = 0.027). Unlike in the success group, hook embedment (9/11, 82%) or IVC filter endothelialization (2/11, 18%) within the wall of the IVC were observed in the failure group using two-dimensional venography. CONCLUSION: When using advanced techniques for IVC filter removal, females are at a higher risk of failure compared to males. Hook embedment and IVC filter endothelialization within the IVC wall, rather than penetration of the IVC wall, are crucial factors in failure of IVC filter removal using advanced techniques.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。