Quantitative and qualitative assessment of glymphatic flux using Evans blue albumin

使用伊文思蓝白蛋白定量和定性评估淋巴通量

阅读:12
作者:Michael S Wolf, Yaming Chen, Dennis W Simon, Henry Alexander, Mark Ross, Gregory A Gibson, Miora D Manole, Hülya Bayır, Patrick M Kochanek, Robert S B Clark

Background

The glymphatic system is a proposed pathway for clearance of proteins and macromolecules from brain, and disrupted glymphatic flux is implicated in neurological disease. We capitalized on colorimetric, fluorescent, and protein-binding properties of Evans blue to evaluate glymphatic flux. New method: Twenty-five μL of 1% Evans blue-labeled albumin (EBA) in artificial cerebrospinal fluid (aCSF) was injected into the intracisternal space of anesthetized postnatal day 17 rats. Serum was collected at various time points after injection (n = 37) and EBA was measured spectrophotometrically. In separate rats (n = 3), a cranial window was placed over the parietal cortex and EBA transit was evaluated using in vivo multiphoton microscopy. Separate rats (n = 6) were processed for immunohistochemistry to examine localization of EBA. In some rats, intracranial pressure (ICP) was increased via intracisternal injection of aCSF.

Conclusion

We present a novel technique for simultaneous quantitative and qualitative evaluation of glymphatic flux in rats.

Methods

Transit of EBA from CSF to serum could be quantified spectrophotometrically without radioactive labeling. Glymphatic flux could also be qualitatively evaluated using EBA fluorescence.

Results

EBA was detected in serum as early as 30 min, was maximal at 4 h, and was undetectable at 72 h after intracisternal injection. Using intra-vital microscopy and immunohistochemistry EBA could be tracked from CSF to perivascular locations. Consistent with removal via glymphatic flux, increasing ICP to 40 mmHg accelerated transit of EBA from CSF to blood. Comparison with existing methods: Transit of EBA from CSF to serum could be quantified spectrophotometrically without radioactive labeling. Glymphatic flux could also be qualitatively evaluated using EBA fluorescence.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。