Laser-Assisted Removal of Embedded Vena Cava Filters: A First-In-Human Escalation Trial in 500 Patients Refractory to High-Force Retrieval

激光辅助取出腔静脉内植入滤器:一项针对500名对强力取出术无效患者的首次人体递增试验

阅读:1

Abstract

Background Many patients are subject to potential risks and filter-related morbidity when standard retrieval methods fail. We evaluated the safety and efficacy of the laser sheath technique for removing embedded inferior vena cava filters. Methods and Results Over an 8.5-year period, 500 patients were prospectively enrolled in an institutional review board-approved study. There were 225 men and 275 women (mean age, 49 years; range, 15-90 years). Indications for retrieval included symptomatic acute inferior vena cava thrombosis, chronic inferior vena cava occlusion, and/or pain from filter penetration. Retrieval was also offered to prevent risks from prolonged implantation and potentially to eliminate need for lifelong anticoagulation. After retrieval failed using 3X standard retrieval force (6-7 lb via digital gauge), treatment escalation was attempted using laser sheath powered by 308-nm XeCl excimer laser system (CVX-300; Spectranetics). We hypothesized that the laser-assisted technique would allow retrieval of >95% of embedded filters with <5% risk of major complications and with lower force. Primary outcome was successful retrieval. Primary safety outcome was any major procedure-related complication. Laser-assisted retrieval was successful in 99.4% of cases (497/500) (95% CI, 98.3%-99.9%) and significantly >95% (P<0.0001). The mean filter dwell time was 1528 days (range, 37-10 047; >27.5 years]), among retrievable-type (n=414) and permanent-type (n=86) filters. The average force during failed attempts without laser was 6.4 versus 3.6 lb during laser-assisted retrievals (P<0.0001). The major complication rate was 2.0% (10/500) (95% CI, 1.0%-3.6%), significantly <5% (P<0.0005), 0.6% (3/500) (95% CI, 0%-1.3%) from laser, and all were successfully treated. Successful retrieval allowed cessation of anticoagulation in 98.7% (77/78) (95% CI, 93.1%-100.0%) and alleviated filter-related morbidity in 98.5% (138/140) (95% CI, 96.5%-100.0%). Conclusions The excimer laser sheath technique is safe and effective for removing embedded inferior vena cava filters refractory to high-force retrieval. This technique may allow cessation of filter-related anticoagulation and can be used to prevent and alleviate filter-related morbidity. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT01158482.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。