Detection of the genial spinal canal in atrophic mandibles with a CBCT: a cadaver study

利用锥形束CT检测萎缩下颌骨中的颏椎管:一项尸体研究

阅读:1

Abstract

OBJECTIVES: The use of a single midline implant to retain a complete mandibular denture when more implants cannot be used is an incipient treatment modality. However, in the mandibular symphysis, the genial spinal canal (GSC) is an anatomical structure with neurovascular content that can be harmed during dental implant surgery. The purpose of the present study was to use CBCT of edentulous atrophic cadaver mandibles and evaluate how often the simulated placement of a single midline implant would contact the GSC if present. METHODS: CBCT scans of 47 edentulous cadaver mandibles were performed. A digital simulation of the placement of a single midline implant (3.8 × 11.0 mm) was performed, and the implant-GSC contact was evaluated. RESULTS: A GSC was detected in the CBCT scan of all atrophic mandibles. In 42 cases (89.4%), the single midline implant contacted the GSC. On average, the five cases without GSC contact had a higher alveolar ridge (4.1 mm) and a lower GSC (0.79 mm) than did the cases with GSC contact. CONCLUSIONS: CBCT scans can adequately detect the GSC during pre-surgical diagnostics. There is a high risk of implant-GSC contact during surgery of the anterior mandible. However, the clinical relevance of such a contact is not known yet, because none of the clinical studies evaluating a single midline implant has reported any implant-GSC contact-related complications.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。