Novel A20-gene-eluting stent inhibits carotid artery restenosis in a porcine model

新型A20基因洗脱支架在猪模型中抑制颈动脉再狭窄

阅读:1

Abstract

BACKGROUND: Carotid artery stenosis is a major risk factor for ischemic stroke. Although carotid angioplasty and stenting using an embolic protection device has been introduced as a less invasive carotid revascularization approach, in-stent restenosis limits its long-term efficacy and safety. The objective of this study was to test the anti-restenosis effects of local stent-mediated delivery of the A20 gene in a porcine carotid artery model. MATERIALS AND METHODS: The pCDNA3.1EHA20 was firmly attached onto stents that had been collagen coated and treated with N-succinimidyl-3-(2-pyridyldithiol)propionate solution and anti-DNA immunoglobulin fixation. Anti-restenosis effects of modified vs control (the bare-metal stent and pCDNA3.1 void vector) stents were assessed by Western blot and scanning electron microscopy, as well as by morphological and inflammatory reaction analyses. RESULTS: Stent-delivered A20 gene was locally expressed in porcine carotids in association with significantly greater extent of re-endothelialization at day 14 and of neointimal hyperplasia inhibition at 3 months than stenting without A20 gene expression. CONCLUSION: The A20-gene-eluting stent inhibits neointimal hyperplasia while promoting re-endothelialization and therefore constitutes a novel potential alternative to prevent restenosis while minimizing complications.