Stereotactic radiosurgery for multiple small brain metastases using gamma knife versus single-isocenter VMAT: Normal brain dose based on lesion number and size

采用伽玛刀与单中心容积旋转调强放射外科(VMAT)治疗多发性小型脑转移瘤:基于病灶数量和大小的正常脑剂量

阅读:2

Abstract

PURPOSE: The study evaluates rapid linear accelerator (Linac) single isocenter stereotactic radiosurgery (SRS) with Hyperarc for large target numbers. We compared to Gamma Knife (GK), which suffers from long treatment times and investigated causes of differences. METHODS: Linac SRS and GK treatment plans for patients receiving 18 Gy to the gross tumor volume (GTV) were evaluated for mean brain dose and volume of brain receiving 12 Gy or more (V12 Gy) as toxicity correlates. Further investigations included patient-based and simulations of 1-33 brain metastases to compare the ability of Linac SRS and GK to separate adjacent and distant lesions. RESULTS: For three patients (33, 33, and 18 metastases), GK reduced mean brain dose (2.89 Gy, 2.38 Gy, 2.79 Gy) compared to 2.5 mm microMLCs (4.36 Gy, 4.75 Gy, 4.26 Gy, p = 0.027) and 5 mm MLCs (4.71 Gy, 5.22 Gy, 4.60 Gy, p = 0.024). GK also improved V12 Gy (13.29 cc, 11.62 cc, 33.79 cc) compared to microMLC (25.31 cc, 30.91 cc, 54.71 cc, p = 0.019) and MLC (31.69 cc, 33.68 cc, 54.71 cc). This must be balanced with GK treatment times (5-11 h). GK achieved 50% prescription line separation at smaller distances (1.8-7.6 mm) than microMLC (7.7-10.2 mm) or MLC (8.8-12.2 mm) for 0.5-1.0 cm targets (4-8 mm collimator single shot). For 1.5 cm targets (16 mm shot) results were mixed (GK 5.4-17 mm, microMLC 9.5-11.2 mm, MLC 9.5-11.3 mm). A 7.7 cm simulation cube was then incrementally filled with 0.5 cm or 1.0 cm equidistant targets. GK plan mean brain dose increased 0.04 Gy/target (1.08 Gy mean/27 targets) compared to 0.14 Gy/target for microMLC (3.78 Gy mean/27 targets) for 0.5 cm targets, with differences diminishing for 1.0 cm targets (GK 0.15 Gy/target, microMLC 0.17 Gy/target). CONCLUSIONS: For numerous small metastases GK improves dosimetry but has exceedingly long treatment times. GK improves dose separation for adjacent lesions < 1.0 cm and conformity for small (∼0.5 cm) targets. GK and Linac differences are small for individual targets but compound over many targets. V12 Gy limits in the NCIC CE.7 trial protocol mandate dose modifications for Linac SRS but not GK.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。