Novel utilization and quantification of Xsight diaphragm tracking for respiratory motion compensation in Cyberknife Synchrony treatment of liver tumors

在Cyberknife Synchrony治疗肝肿瘤中,Xsight膈肌追踪技术在呼吸运动补偿方面的新应用和量化

阅读:2

Abstract

PURPOSE: The Xsight lung tracking system (XLTS) utilizes an advanced image processing algorithm to precisely identify the position of a tumor and determine its location in orthogonal x-ray images, instead of finding fiducials, thereby minimizing the risk of fiducial insertion-related side effects. To assess and gauge the effectiveness of CyberKnife Synchrony in treating liver tumors located in close proximity to or within the diaphragm, we employed the Xsight diaphragm tracking system (XDTS), which was based on the XLTS. METHODS: We looked back at the treatment logs of 11 patients (8/11 [XDTS], 3/11 [Fiducial-based Target Tracking System-FTTS]) who had liver tumors in close proximity to or within the diaphragm. And the results are compared with the patients who undergo the treatment of FTTS. The breathing data information was calculated as a rolling average to reduce the effect of irregular breathing. We tested the tracking accuracy with a dynamic phantom (18023-A) on the basis of patient-specific respiratory curve. RESULTS: The average values for the XDTS and FTTS correlation errors were 1.38 ± 0.65  versus 1.50 ± 0.26 mm (superior-inferior), 1.28 ± 0.48 versus 0.40 ± 0.09 mm (left-right), and 0.96 ± 0.32  versus 0.47 ± 0.10 mm(anterior-posterior), respectively. The prediction errors for two methods of 0.65 ± 0.16  versus 5.48 ± 3.33 mm in the S-I direction, 0.34 ± 0.10 versus 1.41 ± 0.76 mm in the A-P direction, and 0.22 ± 0.072  versus 1.22 ± 0.48 mm in the L-R direction. The coverage rate of FTTS slightly less than that of XDTS, such as 96.53 ± 8.19% (FTTS) versus 98.03 ± 1.54 (XDTS). The prediction error, the motion amplitude, and the variation of the respiratory center phase were strongly related to each other. Especially, the higher the amplitude and the variation, the higher the prediction error. CONCLUSION: The diaphragm has the potential to serve as an alternative to gold fiducial markers for detecting liver tumors in close proximity or within it. We also found that we needed to reduce the motion amplitude and train the respiration of the patients during liver radiotherapy, as well as control and evaluate their breathing.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。