A new predictive parameter for dose-volume metrics in intensity-modulated radiation therapy planning for prostate cancer: Initial phantom study

前列腺癌调强放射治疗计划中剂量体积指标的新预测参数:初步体模研究

阅读:2

Abstract

BACKGROUND: Organ-at-risk (OAR) sparing is often assessed using an overlap volume-based parameter, defined as the ratio of the volume of OAR that overlaps the planning target volume (PTV) to the whole OAR volume. However, this conventional overlap-based predictive parameter (COPP) does not consider the volume relationship between the PTV and OAR. PURPOSE: We propose a new overlap-based predictive parameter that consider the PTV volume. The effectiveness of proposed overlap-based predictive parameter (POPP) is evaluated compared with COPP. METHODS: We defined as POPP = (overlap volume between OAR and PTV/OAR volume) × (PTV volume/OAR volume). We generated intensity modulated radiation therapy (IMRT) based on step and shoot technique, and volumetric modulated arc therapy (VMAT) plans with the Auto-Planning module of Pinnacle(3) treatment planning system (v14.0, Philips Medical Systems, Fitchburg, WI) using the American Association of Physicists in Medicine Task Group (TG119) prostate phantom. The relationship between the position and size of the prostate phantom was systematically modified to simulate various geometric arrangements. The correlation between overlap-based predictive parameters (COPP and POPP) and dose-volume metrics (mean dose, V(70Gy), V(60Gy), and V(37.5 Gy) for rectum and bladder) was investigated using linear regression analysis. RESULTS: Our results indicated POPP was better than COPP in predicting intermediate-dose metrics. The bladder results showed a trend similar to that of the rectum. The correlation coefficient of POPP was significantly greater than that of COPP in < 62 Gy (82% of the prescribed dose) region for IMRT and in < 55 Gy (73% of the prescribed dose) region for VMAT regarding the rectum (p < 0.05). CONCLUSIONS: POPP is superior to COPP for creating predictive models at an intermediate-dose level. Because rectal bleeding and bladder toxicity can be associated with intermediate-doses as well as high-doses, it is important to predict dose-volume metrics for various dose levels. POPP is a useful parameter for predicting dose-volume metrics and assisting the generation of treatment plans.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。