Off-isocentric VMAT technique for breast cancer: Effective dose reduction to organs at risk and its applicability based on patient anatomy

非等中心容积调强放射治疗(VMAT)技术在乳腺癌治疗中的应用:有效降低危及器官的剂量及其基于患者解剖结构的适用性

阅读:2

Abstract

PURPOSE: This study aims to explore the off-isocentric volumetric modulated arc therapy (offVMAT) technique for breast cancer and determine its applicability based on patient anatomical parameters. METHODS: We retrospectively analyzed 44 breast cancer patients with varied lymph node involvement using different arc designs. Off-isocentric techniques were benchmarked against previously published arc techniques: classic arcs (clVMAT), tangential arcs (tVMAT), and split arcs (spVMAT). During optimization, target coverage was made for all plans as close as possible to the criteria D99% > 95% and Dmax < 110% of the prescribed dose. A novel patient categorization, based on anatomical parameters (auxiliary structures) rather than lymph node involvement, is introduced. This categorization considers the volume of ipsilateral organs at risk (OARs) adjacent to the target. A binary regression model was developed on these anatomical parameters. It predicts the likelihood of offVMAT (P[offVMAT]) achieving better criteria. RESULTS: Using the regression model, patients were divided into two groups: P(offVMAT) > 0.5 and P(offVMAT) < 0.5. For the P(offVMAT) > 0.5 group, most tVMAT plans are unable to achieve the clinical objectives. Comparing offVMAT with spVMAT, offVMAT exhibited better dose parameters for the heart (V20, V10, and D2 are 7.1, 2.4, and 1.5 times lower respectively), ipsilateral lung (V20, V10, V5 and the mean dose are 1.4, 1.3, 1.2, and 1.2 times lower respectively). The average doses to the contralateral side are consistent. In the P(offVMAT) < 0.5 group, the tVMAT technique showed increased doses at medium and high levels, yet reduced doses in contralateral OARs compared to spVMAT and offVMAT. spVMAT showed lower doses in the contralateral lung relative to the offVMAT technique, while clVMAT trailed in both groups. Validation of the model yielded a 90% accuracy rate. CONCLUSIONS: The new off-isocentric breast planning technique effectively reduces doses to ipsilateral OARs, maintaining acceptable contralateral mean doses. This technique has an advantage over other techniques for patients with intricate anatomies. It is evaluated using anatomical parameters, which are also used to build binary regression model, which shows the dependence of anatomical parameters on whether offVMAT is preferred for individual patients. Also, such anatomical parameters provide a more objective and precise comparison between different planning techniques.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。