Comparison of anatomically informed class solution template trajectories with patient-specific trajectories for stereotactic radiosurgery and radiotherapy

解剖学信息分类解决方案模板轨迹与立体定向放射外科和放射治疗患者特异性轨迹的比较

阅读:1

Abstract

Class solution template trajectories are used clinically for efficiency, safety, and reproducibility. The aim was to develop class solutions for single cranial metastases radiotherapy/radiosurgery based on intracranial target positioning and compare to patient-specific trajectories in the context of 4π optimization. Template trajectories were constructed based on the open-source Montreal Neurological Institute (MNI) average brain. The MNI brain was populated with evenly spaced spherical target volumes (2 cm diameter, N = 243) and organs-at-risk (OARs) were identified. Template trajectories were generated for six anatomical regions (frontal, medial, and posterior, each with laterality dependence) based on previously published 4π optimization methods. Volumetric modulated arc therapy (VMAT) treatment plans generated using anatomically informed template 4π trajectories and patientspecific 4π trajectories were compared against VMAT plans from a standard four-arc template. Four-arc optimization techniques were compared to the standard VMAT template by placing three spherical targets in each of six anatomical regions of a test patient. This yielded 54 plans to compare various plan quality metrics. Increasing plan technique complexity, the total number of OAR maximum dose reductions compared to the standard arc template for the 6 anatomical classes was 4+/-2 (OFIXEDc) and 7+/-2 (OFIXEDi). In 65.6% of all cases, optimized fixed-couch positions outperformed the standard-arc template. Of the three comparisons, the most complex (OFIXEDi) showed the greatest statistical significance compared to the least complex (VMATi) across 12 plan quality metrics of maximum dose to each OAR, V12Gy, total plan Monitor Units, conformity index, and gradient index (p < 0.00417). In approximately 70% of all cases, 4π optimization methods outperformed the standard-arc template in terms of maximum dose reduction to OAR, by exclusively changing the arc geometry. We conclude that a tradeoff exists between complexity of a class solution methodology compared to patient-specific methods for arc selection, in the context of plan quality improvement.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。