Automatic measurement of air gap for proton therapy using orthogonal x-ray imaging with radiopaque wires

利用正交X射线成像和不透射线自动测量质子治疗中的气隙

阅读:1

Abstract

PURPOSE: The main objective of this study was to develop a technique to accurately determine the air gap between the end of the proton beam compensator and the body of the patient in proton radiotherapy. METHODS: Orthogonal x-ray image-based automatic coordinate reconstruction was used to determine the air gap between the patient body surface contour and the end of beam nozzle in proton radiotherapy. To be able to clearly identify the patient body surface contour on the orthogonal images, a radiopaque wire was placed on the skin surface of the patient as a surrogate. In order to validate this method, a Rando(®) head phantom was scanned and five proton plans were generated on a Mevion S250 Proton machine with various air gaps in Varian Eclipse Treatment Planning Systems (TPS). When setting up the phantom in a treatment room, a solder wire was placed on the surface of the phantom closest to the beam nozzle with the knowledge of the beam geometry in the plan. After the phantom positioning was verified using orthogonal kV imaging, the last pair of setup kV images was used to segment the solder wire and the in-room coordinates of the wire were reconstructed using a back-projection algorithm. Using the wire as a surrogate of the body surface, we calculated the air gaps by finding the minimum distance between the reconstructed wire and the end of the compensator. The methodology was also verified and validated on clinical cases. RESULTS: On the phantom study, the air gap values derived with the automatic reconstruction method were found to be within 1.1 mm difference from the planned values for proton beams with air gaps of 85.0, 100.0, 150.0, 180.0, and 200.0 mm. The reconstruction technique determined air gaps for a patient in two clinical treatment sessions were 38.4 and 41.8 mm, respectively, for a 40 mm planned air gap, and confirmed by manual measurements. There was strong agreement between the calculated values and the automatically measured values, and between the automatically and manually measured values. CONCLUSIONS: An image-based automatic method has been developed to conveniently determine the air gap of a proton beam, directly using the orthogonal images for patient positioning without adding additional imaging dose to the patient. The method provides an objective, accurate, and efficient way to confirm the target depth at treatment to ensure desired target coverage and normal tissue sparing.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。