The Challenges of Apnea Tests in the Determination of Brain Death in Child Patient on Extracorporeal Membrane Oxygenation

体外膜肺氧合患儿脑死亡判定中呼吸暂停试验的挑战

阅读:1

Abstract

Extracorporeal membrane oxygenation (ECMO) is a life-support modality used in patients with refractory cardiac and/or respiratory failure. ECMO is linked with high risk of neurological complications including brain death. Neurological monitoring during ECMO is important for identifying patients who are suspected of brain death and allows to discontinue ineffective medical treatments. Brain death (BD) is an irreversible cessation of functions of the entire brain, containing the brainstem. The apnea test (AT) is an essential part in the clinical determination of brain death. An apnea test is by neurologic criteria compulsory to confirm BD in China. Apnea test remains a problem for patients receiving ECMO. Currently, there are not any consensus guidelines for the safe performance of AT during ECMO. We report the case of a child on venous-arterial ECMO post-cardiac arrest in whom we performed an apnea test to determine death by neurologic criteria. Decreasing sweep gas flow rate 0.05 L/min every 5 min led to a PaCO(2) increase of more than 20 mmHg of apnea. The results of the AT was positive. When he was determined brain dead, his parents decided to donate his organs. AT can be performed on potential donor children on ECMO by decreasing the sweep gas flow. It is a safe and effective method and is important for BD determination.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。