A Metascore of Multiple Imaging Methods to Measure Long-Term Glaucoma Structural Progression

多种影像学方法综合评分用于测量青光眼长期结构进展

阅读:2

Abstract

PURPOSE: To develop a structural metascore (SMS) that combines measurements from different devices and expresses them on a single scale to facilitate their long-term analysis. METHODS: Three structural measurements (Heidelberg Retina Tomograph II [HRT] rim area, HD-Cirrus optical coherence tomography [OCT] average retinal nerve fiber layer [RNFL] thickness, Spectralis OCT RNFL global thickness) were normalized on a scale of 0 to 100 and converted to a reference value. The resultant metascores were plotted against time. SMS performance was evaluated to predict future values (internal validation), and correlations between the average grades assigned by three clinicians were compared with the SMS slopes (external validation). RESULTS: The linear regression fit with the variance approach, and adjustment to a Spectralis equivalent was the best-performing approach; this was denominated metascore. Plots were created for 3416 eyes of 1824 patients. The average baseline age (± standard deviation) was 69.8 (±13.9), mean follow-up was 11.6 (±4.7) years, and mean number of structural scans per eye was 10.0 (±4.7). The mean numbers of scans per device were 3.8 (±2.5), 5.0 (±2.9), and 1.3 (±3.0) for HRT, Cirrus, and Spectralis, respectively. The metascore slopes' median was -0.3 (interquartile range 1.1). Correlations between the average grades assigned by the three clinicians and the metascore slopes were -0.51, -0.49, and -0.69 for the first (structural measurement printouts alone), second (metascore plots alone), and third (printouts + metascore plots) series of gradings, respectively. The average absolute predictive ability was 7.63/100 (whereas 100 = entire normalized scale). CONCLUSIONS: We report a method that converts Cirrus global RNFL and HRT global rim area normalized measurements to Spectralis global RNFL equivalent values to facilitate long-term structural follow-up. TRANSLATIONAL RELEVANCE: Because glaucoma changes usually occur slowly, patients are often examined with different instruments during their follow-up, a method that "unifies" structural measurements provided by different devices, which could assist patients' longitudinal structural follow-up.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。