Early Assessment of Circumferential Anterior Segment Structures Following Implantable Collamer Lens V4c Implantation Via SS-OCT

通过 SS-OCT 对植入式胶原蛋白晶状体 V4c 植入术后前节环周结构进行早期评估

阅读:1

Abstract

PURPOSE: To explore early changes in circumferential anterior segment structures following Implantable Collamer Lens (ICL) V4c implantation via swept-source optical coherence tomography (SS-OCT). METHODS: In 103 eyes of 56 myopic patients undergoing ICL V4c surgery, anterior segments were measured via SS-OCT to compute local anterior chamber angle (ACA) parameters on the nasal-temporal (0°-180°), superior-inferior (90°-270°), and superior nasal-inferior temporal (80°-260°) meridians, including angle-opening distance at 500 µm (AOD500), trabecular-iris space area at 500 µm (TISA500), trabecular-iris angle at 500 µm (TIA500), and circumferential ACA parameters, including AOD area at 500 µm (AODA500), trabecular-iris circumference volume at 500 µm (TICV500), and the index and area of iris-trabecular contact (ITC). ACA parameters were compared preoperatively and at 1 week, 1 month, and 3 months postoperatively and compared among quadrants. Mixed-effects model was used to evaluate the parameters correlated with the post-ITC parameters. RESULTS: The mean AOD500, TISA500, TIA500, AODA500, and TICV500 were decreased by 65.4% to 71%, 64.1% to 69.3%, 53.8% to 61.5%, 69.9%, and 69.2%, respectively, at 1 week postoperatively. The ITC index and area values rose from 1.436% ± 4.427% and 0.070 ± 0.254 mm2 to 12.343% ± 13.216% and 0.903 ± 1.304 mm2 (all P < 0.05). No further decreases in ACA parameters were observed beyond 1 week postoperatively (all P > 0.05). Significant differences were observed among quadrants, with the narrowest in the superior-nasal quadrant, followed by the superior quadrant. The 3-month vault was significantly correlated with the ITC index and area at 3 months postoperatively. CONCLUSIONS: Anterior segment structures were significantly shallow at 1 week with no further decreases thereafter. In light of anatomical variability, we recommend circumferential meridian scan to assess angle status, with special attention to the superior-nasal and superior quadrants. TRANSLATIONAL RELEVANCE: We investigated the early changes in circumferential anterior segment structures following ICL V4c implantation, thus providing a better perspective for understanding anterior segment structural characteristics after ICL V4c surgery.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。