Evaluation of lung transplant perfusion using iodine maps from novel spectral detector computed tomography

利用新型光谱探测器计算机断层扫描碘图评估肺移植灌注

阅读:1

Abstract

We report the case of a 51-year-old patient who underwent bilateral lung transplantation and presented with an unstable condition and sepsis 6 days after transplantation. The performed contrast enhanced spectral detector computed tomography (CT) using a dual-layer detector showed absence of perfusion in the left lung on iodine maps, although branches of the pulmonary artery were patent. This prompted retrospective evaluation of CT images and total venous occlusion of the left pulmonary veins was found. Here, iodine maps helped in raising conspicuity of loss of lung perfusion.