C2 quad-screws facilitate 4-rod fixation across the cervico-thoracic junction

C2 四钉可实现颈胸交界处的四杆固定。

阅读:1

Abstract

BACKGROUND: Cervical spine deformity is a potentially devitalizing problem. Contemporary techniques for repair and reconstruction include fusion using rods of tapered diameter alone, or quadruple-rod constructs in which primary rods are joined to floating accessory rods by connectors. Here, we present how we utilized a quadruple-rod construct to perform five C2 to thoracic spine fusions. METHODS: Our hospital electronic medical record revealed five patients who underwent the four rod C2-thoracic spine fixation. Patients ranged in age from 14-years-old to 78-years-old. The mean operative time was 715.8 min (range 549-987 min), and average estimated blood loss was 878 cc (range 40-1800 cc). RESULTS: None of the five patients sustained any intraoperative complications, and none demonstrated progressive kyphotic deformity over the average follow-up interval of 8 months. CONCLUSION: We successfully treated five patients with degenerative or oncologic cervical pathology requiring fixation across the cervicothoracic junction utilizing a 4-rod C2-cervicothoracic fusion technique.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。