The Value of Non-invasive Electrocardiography in Assessing Fetal Status at Term Delivery

无创心电图在评估足月分娩时胎儿状况中的价值

阅读:1

Abstract

BACKGROUND: The electrocardiograph (ECG) is efficient method for the accurate assessment of fetal heart rate. The barriers for accurate assessment are maternal heart rate, uterine contractions and abdominal muscles. Although previous monitoring methods have struggled to overcome these barriers, recent advances have led to a greater degree of success for listening and recording pulse-by-pulse fetal heart rate. OBJECTIVES: A prospective cohort study evaluating the use, reliability and safety of non-invasive electrocardiography, in conjunction with Fetal Heart Rate parameters such as, Short Term Variability (STV) together with umbilical cord PH and Apgar score, during the active phase of childbirth. METHODS: A total of 41 women with single, normal, full-term pregnancies had systematic obstetric monitoring with Monica AN24. 20 had only monitoring and 21 also had and arterial blood flow measurements. pH was measured and correlated with neonatal Apgar score at 1 and 5 min. The study also included a questionnaire about the safety and usability of obstetric monitoring. Statistical analysis was done using IBM SPSS v. 26.0. RESULTS: Mean age was 28.8 years, (SD ± 6.153). Electrocardiogram recordings (ECG) were classified as normal (71%) and suspicious (29%). Baseline between ECGs was different (p = 0.025) similarly for Short term variability (STV) (p <0.0001). BMI did not differentiate SVT rates. Only high acceleration (p <0.029) and small slowdowns had a statistically significant difference between normal and suspected cardiographs (p <0.029). APGAR score did not differ, whereas the umbilical cord pH was different in normal ECGs compared to the suspect (p = 0.012) and STV was also differentiated. A usability and safety survey was conducted after recording with MONIKA AN24, and the response to whether they would accept recording with the device again, was positive for 96% of the 30 responders. CONCLUSION: The present study shows that the use of electrocardiography in obstetrics allows to draw conclusions about the fetal hematopoiesis and oxygenation status. This method could be clinically applied and be an important tool for further screening in embryos that may be hypoxic and to decide whether to continue with a vaginal or cesarean delivery, thereby achieving the goal of reducing perinatal morbidity and mortality.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。