A multicenter analysis of implantable monitoring device-based diagnosis of supraventricular arrhythmia post patent foramen ovale closure: the OCCL-ILR study

一项基于植入式监测设备诊断卵圆孔未闭术后室上性心律失常的多中心分析:OCCL-ILR 研究

阅读:2

Abstract

BACKGROUND: Recent data suggest that the true incidence of atrial fibrillation (AF) after patent foramen ovale (PFO) closure has probably been underestimated, and may differ according to the type of closing device used. OBJECTIVES: On the basis of continuous rhythm monitoring with an implantable device, this study aims to assess the incidence of  supraventricular arrhythmia following PFO closure with the Occlutech PFO device. METHODS: This is a multicentric analysis of consecutive PFO closure patients treated with an Occlutech device between 01/01/2019 and 20/03/2024, with an implantable loop recorder (IRL) (or a pacemaker or implantable cardioverter defibrillator) implanted for at least 3 months preceding the procedure, and with available follow-up for at least 1month post procedure. Primary endpoint was the incidence of patients with new onset supraventricular arrhythmia (AF, atrial flutter or any supraventricular tachycardia) lasting >30 s, post PFO closure. RESULTS: A total of 59 patients met the inclusion criteria. Patients were monitored (95% with ILR) during 284 days (IQR 241.5-374) before, and for 422 days (IQR 237-776) post PFO closure. Supraventricular arrhythmia post PFO closure was reported in 18 patients (31%), with median time-interval until arrhythmia occurrence of 16.5 days (IQR 13-21). A total of 88 supraventricular arrhythmia events (96.6% AF) were documented during follow-up. In 94.4% of patients with supraventricular arrhythmia, new-onset arrhythmia occurred in the first 45 days after PFO closure. Six patients (33.3%) with supraventricular arrhythmia post PFO closure, presented AF episodes beyond 60 days after PFO closure. CONCLUSIONS: In this multicenter retrospective analysis of patients undergoing percutaneous PFO closure with the Occlutech PFO device, implantable continuous rhythm monitoring devices were able to diagnose new-onset supraventricular arrhythmia (97% AF) after PFO closure in 31% of patients. While 94% of new-onset supraventricular arrhythmia events occurred in the first 45 days post-procedure, one-third of patients with arrhythmia post PFO closure presented AF episodes beyond 60 days post procedure.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。