Noblestitch® system for PFO closure: A novel but judicious alternative to traditional devices-A case report

用于卵圆孔未闭封堵的Noblestitch®系统:一种新颖而审慎的传统器械替代方案——病例报告

阅读:2

Abstract

BACKGROUND: Percutaneous suture-mediated patent foramen ovale (PFO) closure has recently been used with the aim of avoiding double-disc nitinol device implantation. This novel technique has been carried out successfully in several centers offering PFO closure with an effective closure rate comparable to conventional double-disc devices. CASE SUMMARY: A 50-year-old man, a pentathlon athlete, suffering from a previous left-sided ischemic stroke, underwent percutaneous closure of a permanent right-to-left shunt via PFO with a large fenestrated septum primum aneurysm at another institution. The NobleStitch® system was successfully implanted using local anesthesia and under angiographic-fluoroscopic monitoring. He was discharged home on aspirin 100 mg daily with a moderate residual shunt on contrast transthoracic echocardiography (cTTE) that persisted unaltered at subsequent controls. After 7 months, unable to resume sporting activity because of physical discomfort and dyspnea on exertion, the patient asked for a second opinion at our Heart and Brain clinic. Two-dimensional (2D) TTE showed septum primum laceration next to a radiopaque polypropylene knot with a moderate bidirectional shunt located at the fenestrated septum primum far from the PFO site. A catheter-based closure of the septal defect was therefore planned under local anesthesia and rotational intracardiac echo monitoring. An equally sized discs 28.5 mm × 28.5 mm Flex II UNI occluder (Occlutech GmbH, Jena, Germany) was successfully implanted across the atrial septal defect without complications. The patient was discharged in good clinical conditions; dual antiplatelet therapy (aspirin 100 mg/daily and clopidogrel 75 mg/daily) was recommended for 2 months and then single antiplatelet therapy (aspirin100 mg/daily) up to 6 months. Abolition of the residual shunt was confirmed at 1- and 6-month follow-up by contrast transcranial Doppler and 2D color Doppler cTTE. DISCUSSION: Closing a PFO with a suture-base system, without leaving a device implant behind, may be a cutting-edge technology and potential alternative to traditional devices. Nevertheless, meticulous selection of the PFO anatomies by 2D TEE is key to a successful closure procedure in order to avoid complications that must be managed again with a second percutaneous procedure or by surgery.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。