The safety and efficacy of the Mo.Ma system device for carotid artery stenting: A single-center experience from Taiwan

Mo.Ma系统装置用于颈动脉支架置入术的安全性和有效性:来自台湾的单中心经验

阅读:1

Abstract

BACKGROUND: Proximal protection devices, such as the Mo.Ma system provides better neurological outcomes than the distal filter system in the carotid artery stenting (CAS) procedure. This study first evaluated the safety and efficacy of the Mo.Ma system during CAS in a single tertiary referral hospital from Taiwan. The outcomes of distal vs. proximal embolic protection devices were also studied. METHODS: A total of 294 patients with carotid artery stenosis who underwent the CAS procedure were retrospectively included and divided into two groups: 152 patients in the distal filter system group and 142 patients in the Mo.Ma system. The outcomes of interest were compared between the two groups. The factors contributing to occlusion intolerance (OI) in the Mo.Ma system were evaluated. RESULTS: The procedure success rates were more than 98% in both groups. No major stroke occurred in this study. The minor stroke rates were 2.8% (4/142) and 4.6% (7/152) in the Mo.Ma system and filter system, respectively (p = 0.419). Patients with hypoalbuminemia significantly predicted the risk of stroke with an odds ratio of 0.08 [95% confidence interval (CI), 0.01-0.68, p = 0.020] per 1 g/day of serum albumin in the filter group. A total of 12 patients developed OI in the Mo.Ma system (12/142, 8%). Low occlusion pressure predicted the occurrence of OI in the Mo.Ma group with the hazard ratios of 0.88 (95% CI: 0.82-0.96) and 0.90 (95% CI: 0.84-0.98) per 1 mmHg of occlusion systolic pressure (OSP) and diastolic pressure (ODP), respectively. We further indicated that patients with an OSP of ≥60 mmHg or an ODP of ≥44 mmHg could tolerate the procedure of occlusion time up to 400 s, while patients with an OSP of <49 mmHg or an ODP of <34 mmHg should undergo the procedure of occlusion time less than 300 s to prevent the occurrence of OI. CONCLUSION: We have demonstrated the safety and effectiveness of the Mo.Ma system during CAS in an Asia population. By reducing the occlusion time, our study indicated a lower risk of OI in the Mo.Ma system and proposed the optimal occlusion time according to occlusion pressure to prevent OI during the CAS procedure. Further large-scale and prospective studies are needed to verify our results.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。