Development and Investigation of a Wearable Aid for a Load Carriage Task

开发和研究用于负重搬运任务的可穿戴辅助设备

阅读:1

Abstract

Anterior load carriage tasks are common and can lead to musculoskeletal disorders such as lower back pain. The objectives of this study were to develop a wearable carriage aid and examine its effectiveness on physical demands while considering the potential moderating influence of the carried load. The study consisted of two within-subject factors: device and load. For the former, two levels were tested: with and without the device worn. For the latter, two loads were examined: 15 and 30% of each individual's body mass. Sixteen participants walked on a treadmill for five minutes at a constant speed for each condition. Physical demands were quantified using objective (EMG-based) and subjective (discomfort) measures. Wearing the device reduced static and median anterior deltoid, trapezius, and biceps brachii muscle activations. Increasing the carried load increased most physical demand measures. Two significant Device×Load interactions were observed; for the anterior deltoid and trapezius median activation measures, the influence of increasing load was lower when the device was worn. While slightly increasing perceived discomfort in the lower back, wearing the device reduced shoulder, neck, and hand/wrist discomfort. While the study demonstrated a potential for the device, future work is required under more realistic and diverse testing conditions.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。