BACKGROUND/AIM: Strain elastography has the disadvantage of being operator-dependent. Interobserver variability is observed during image acquisition and interpretation. This study aimed to analyze the interobserver and intermethod variability of strain elastography in image interpretation and evaluate the diagnostic performance combining elasticity score and strain ratio with ultrasonography. MATERIALS AND METHODS: A retrospective study was conducted on 70 breast lesions evaluated with B-mode ultrasonography and strain elastography. B-mode ultrasonography findings, elasticity scores, and strain ratio values were evaluated using static images by two radiologists. BI-RADS assessment of the lesions and the decision of both observers as to whether the biopsy was required using B-mode ultrasonography, and the combined ultrasonography+elasticity score, and the combined ultrasonography+elasticity score+strain ratio were compared with the histopathological results. Also, the interobserver agreement was analyzed for all the combinations. RESULTS: There was very good agreement (weighted κ = 0.865) between the observers for the elasticity scores. Very good agreement was observed between the observers for BI-RADS assessments using the combined ultrasonography+elasticity score and the combined ultrasonography+elasticity score+strain ratio (weighted κ = 0.848, and 0.902, respectively). Area under the curve of B-mode ultrasonography, the combined B-mode ultrasonography+elasticity score, and the combined B-mode ultrasonography+elasticity score+strain ratio, were calculated as 0.859, 0.866, and 0.916 for observer 1, and 0.851, 0.829, and 0.916 for observer 2, respectively. There were no statistically significant differences between the observers’ diagnostic performances in any of the combinations (P = 0.703, 0.067, and 0.972, respectively). CONCLUSION: In the evaluation and further assessment of breast lesions, semiquantitative strain ratio calculation may help improve diagnostic accuracy by reducing interpretational variety, when used together with B-mode ultrasonography and elasticity scoring, especially for inexperienced individuals.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。