Effect of manual hyperinflation with versus without positive end-expiratory pressure on dynamic compliance in pediatric patients following congenital heart surgery: A randomized controlled trial

手动过度充气联合或不联合呼气末正压对先天性心脏病术后患儿动态肺顺应性的影响:一项随机对照试验

阅读:2

Abstract

BACKGROUND: We aimed to compare the effect of manual hyperinflation with versus without positive end-expiratory pressure (PEEP) on dynamic compliance of the respiratory system in pediatric patients undergoing congenital heart surgery; to assess the safety of the technique in this population. METHODS: This was a randomized controlled trial conducted at the pediatric intensive care unit (PICU) of a tertiary-care hospital. Patients admitted to the PICU following cardiac surgery and receiving postoperative mechanical ventilation were randomized to the experimental or control group. Patients in the experimental group (n = 14) underwent manual hyperinflation with a PEEP valve set at 5 cm H2O, once daily, during the first 48 hours after surgery. Patients allocated to the control group (n = 16) underwent manual hyperinflation without PEEP, at the same time points. Lung mechanics was assessed before (T0) and 5 minutes (T5) after manual hyperinflation. The primary endpoint was dynamic compliance. Secondary outcomes included oxygen saturation index, duration of mechanical ventilation, length of stay, 28-day mortality and safety. RESULTS: Demographic and clinical characteristics were comparable in both groups. There was no significant difference in dynamic compliance between times in each group (Day 1: (mean) 0.78 vs 0.81 and 0.70 vs 0.77; Day 2: 0.85 vs 0.78 and 0.67 vs 0.68 mL/kg/cm H2O, in experimental and control groups, respectively; P > .05). Mean deltas of dynamic compliance were not significantly different between groups. The proportion of patients extubated <72 hours after surgery was similar in experimental and control groups (43% vs 50%, respectively; P = .73). Oxygen saturation index, length of stay, and 28-day mortality were not significantly different between groups. None of the patients had hemodynamic instability. CONCLUSIONS: Manual hyperinflation was safe and well tolerated in pediatric patients following surgery for congenital heart disease. No significant change in dynamic compliance of the respiratory system or in oxygenation was observed with the use of manual hyperinflation with or without PEEP in this population.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。