Perinatal outcome after vacuum assisted delivery with digital feedback on traction force; a randomised controlled study

采用数字反馈牵引力进行真空辅助分娩后的围产期结局:一项随机对照研究

阅读:2

Abstract

BACKGROUND: Low and mid station vacuum assisted deliveries (VAD) are delicate manual procedures that entail a high degree of subjectivity from the operator and are associated with adverse neonatal outcome. Little has been done to improve the procedure, including the technical development, traction force and the possibility of objective documentation. We aimed to explore if a digital handle with instant haptic feedback on traction force would reduce the neonatal risk during low or mid station VAD. METHODS: A two centre, randomised superiority trial at Karolinska University Hospital, Sweden, 2016-2018. Cases were randomised bedside to either a conventional or a digital handle attached to a Bird metal cup (50 mm, 80 kPa). The digital handle measured applied force including an instant notification by vibration when high levels of traction force were predicted according to a predefined algorithm. Primary outcome was a composite of hypoxic ischaemic encephalopathy, intracranial haemorrhage, seizures, death and/or subgaleal hematoma. Three hundred eighty low and mid VAD in each group were estimated to decrease primary outcome from six to 2 %. RESULTS: After 2 years, an interim analyse was undertaken. Meeting the inclusion criteria, 567 vacuum extractions were randomized to the use of a digital handle (n = 296) or a conventional handle (n = 271). Primary outcome did not differ between the two groups: (2.7% digital handle vs 2.6% conventional handle). The incidence of primary outcome differed significantly between the two delivery wards (4% vs 0.9%, p < 0.05). A recalculation of power revealed that 800 cases would be needed in each group to show a decrease in primary outcome from three to 1 %. This was not feasible, and the study therefore closed. CONCLUSIONS: The incidence of primary outcome was lower than estimated and the study was underpowered. However, the difference between the two delivery wards might reflect varying degree of experience of the technical equipment. An objective documentation of the extraction procedure is an attractive alternative in respect to safety and clinical training. To demonstrate improved safety, a multicentre study is required to reach an adequate cohort. This was beyond the scope of the study. TRIAL REGISTRATION: ClinicalTrials.gov NCT03071783 , March 1, 2017, retrospectively registered.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。