A novel tamponade agent for management of post partum hemorrhage: adaptation of the Xstat mini-sponge applicator for obstetric use

一种用于治疗产后出血的新型止血剂:Xstat迷你海绵敷贴器在产科中的应用改良

阅读:2

Abstract

BACKGROUND: Although uterine tamponade is an effective treatment for postpartum hemorrhage (PPH), current methods have key limitations in their use, particularly in low resource settings. The XStat™ Mini Sponge Dressing (MSD) is approved for the management of non-compressible wounds in the battlefield/trauma setting. The MSD applies highly compressed medical sponges capable of stopping high-flow arterial bleeding within seconds. The objective of our study was to adopt the MSD for use in managing PPH. METHODS: We performed desktop testing using a uterine model with pressure sensors to compare key design elements of the obstetrical prototype MSD (fundal pressure achieved, reduction in fluid loss, time to deploy, and time to remove) with alternativetechniques (uterine packing, balloon tamponade). To evaluate safety, we delivered the fetus of pregnant ewes by cesarean section and used the prototype to deliver the MSD into one uterine horn, and closed the hysterotomy. We followed the clinical recovery of animals (n = 3) over 24 h, and then removed the reproductive tract for histologic evaluation. To evaluate late effects, we surgically removed the MSDs after 24 h, and followed the clinical recovery of animals (n = 6) for an additional seven days before tissue removal. RESULTS: The obstetrical prototype has a long tapered delivery system designed to be deployed during vaginal examination, and administers three times the volume of the approved MSD trauma bandage. The MSD are deployed within a mesh bag to facilitate removal by vaginaltraction. On desktop testing, the MSD resulted in the highest average fundal pressure (113 mmHg), followed by the MSD bag device (85.8 mmHg), gauze packing (15.5 mmHg), and the uterine balloon (8.2 mmHg). The MSD bag test group achieved the largest fluid flow reduction of -74%, followed by gauze packing (-55%), MSD (-35%), and uterine balloon (-19%). Animal testing demonstrated good uterine fill with no evidence of adverse clinical recovery, uterine trauma or infection at 24 h, or up to 7 days following device removal. CONCLUSION: We adapted a highly effective trauma dressing and applicator for use in the treatment of severe PPH. Preliminary desktop and animal testing provide a basis for initial clinical trials in women.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。