Optimising the collection of female genital tract fluid for cytokine analysis in pregnant women

优化孕妇生殖道液的采集以进行细胞因子分析

阅读:5
作者:C S Short, R Quinlan, P Bennett, R J Shattock, G P Taylor

Conclusion

Both methods of collection are robust for measurement of FGF cytokines during pregnancy. We recommend CVF collection using a menstrual cup as a viable option in pregnant women for high dimensional biological techniques.

Methods

A prospective study of HIV-uninfected pregnant women comparing two methods of FGF collection: polyvinyl acetal sponge collection of cervical fluid (CF) and menstrual cup collection of cervicovaginal fluid (CVF). Samples were collected at 3 time points across the second and third trimesters: 14-21, 22-25 and 26-31 weeks. Multiplex chemi-luminescent assays were used to measure: IFN-γ, IL-1β, IL-2, IL-4, IL-6, IL-8, IL-10, IL-12, IL-13 and TNF-α. Optimal methodology for cytokine normalisation (sample weight, volume and total protein) was explored.

Results

All cytokines were measurable in both fluid types. IL-1β, IL-8 and IL-6 were detected at the highest concentrations (ranking order CF > CVF > plasma). CVF collection was simpler, provided the largest volume of sample (median 0.5 g) with the potential for undiluted usage, and allowed for self-insertion. CF cytokine concentrations were intrinsically associated with sample weight and protein concentration however CVF cytokines were independent of these.