Integrity performance assessment of a closed system transfer device syringe adaptor lock as a terminal closure for Luer-Lock syringes

对封闭式系统转移装置注射器适配器锁作为鲁尔锁注射器的末端闭合装置进行完整性性能评估

阅读:1

Abstract

OBJECTIVES: To investigate the container closure integrity of a closed system transfer device syringe adaptor lock in combination with disposable Luer-Lock syringes as the terminal closure device. The UK National Health Service (NHS) Pharmaceutical Quality Assurance Committee (PQAC) requires syringe integrity data for final storage devices of aseptic products such as chemotherapy drugs when prepared in advance and stored before use, as is standard practice for dose banded drugs. The assessment comprised both physical and microbial integrity testing of the combination closed system/Luer-Lock syringe containers at syringe sizes of 1 mL, 20 mL, and 50 mL. METHODS: Integrity testing was performed as described in the NHS Pharmaceutical Quality Assurance Committee yellow cover document, second edition 2013 'Protocols for the Integrity Testing of Syringes', with Chemfort (Simplivia, IL) syringe adaptor lock (SAL) devices as replacement for sterile blind hubs. Microbiological integrity was assessed according to method 1 part 1.4 using Brevundimonas diminuta at 32°C for up to 14 days of contact time. Two positive control devices per syringe size were tested using a blind hub cap as closure which was loosened before the test. Physical integrity was assessed using method 3 of the yellow cover document which is a dye intrusion method. Dye intrusion was assessed both visually and using a validated ultraviolet-visible spectrophotometer method. For each size/batch of test articles a positive control device (n=1) was assessed using a wire wrapped around the syringe plunger tip deliberately compromising integrity. Negative controls for each size (n=1) consisted of devices not immersed in methylene blue dye. RESULTS: Chemfort syringe adaptor lock/Luer-Lock syringe combinations were shown to be: (1) free of microbiological contamination after 14 days of contact time (n=60); and (2) free of dye intrusion at all syringe sizes tested (n=61 in total). The data demonstrate 100% closure integrity of the final container system when the Chemfort syringe adaptor lock replaces the syringe hub as the terminal closure device. All positive control devices demonstrated system suitability as container integrity was compromised in all positive control tests. All negative controls were negative for microbial and dye intrusion. CONCLUSIONS: Syringe adaptor lock components complied with the NHS Pharmaceutical Quality Assurance Committee yellow cover document syringe integrity requirements when used as the terminal closure of Luer-Lock disposable syringes from 1 mL up to 50 mL. Therefore, syringe adaptor lock (Chemfort) can be used as the terminal closure system for pre-filled syringes of chemotherapeutic drug products prepared in advance in UK NHS pharmacy technical services.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。