Case report: Management of recurrent pupillary optic capture with sutureless surgical technique using 7-0 polypropylene flange

病例报告:采用7-0聚丙烯法兰无缝线手术技术治疗复发性瞳孔光学捕获

阅读:1

Abstract

BACKGROUND: To report a novel surgical technique for recurrent pupillary optic capture after flanged intraocular lens (IOL) fixation. METHODS: In this retrospective case series, we detail our use of two parallel 7-0 polypropylene sutures passed between the iris plane and the optic of scleral-fixated IOL to address pupillary optic capture. Flanges were created using ophthalmic cautery to secure it to the sclera without suture. RESULTS: Two eyes with pupillary optic capture underwent a sutureless surgical technique using 7-0 polypropylene flanges. No recurrences of pupillary optic capture were observed during the 1-year follow-up. CONCLUSION: Our sutureless surgical technique using a 7-0 polypropylene flange was an effective, efficient, and less invasive approach for treating recurrent pupillary optic capture.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。