Thermoanalytical and Tensile Strength Studies of Polypropylene Fibre-Reinforced Cement Composites Designed for Tunnel Applications

针对隧道应用设计的聚丙烯纤维增强水泥复合材料的热分析和拉伸强度研究

阅读:1

Abstract

In this article, the thermal and mechanical properties of mortars reinforced with polypropylene (PP) fibres have been studied. Particularly, the effect of polypropylene fibres' addition on the thermal behaviour of fine-grained building mortars at high temperatures was studied using simultaneous thermal analysis. Two types of polypropylene fibres, differing in shape and size, were used as fillers. The thermal behaviour of cement mortar samples with and without fibres was described. Special attention was given to the thermal behaviour of fibre-reinforced cement mortars subjected to the high temperatures of 100 °C, 200 °C, 300 °C, 400 °C, 500 °C, and 600 °C. Comparative studies using simultaneous thermal analysis (STA) were also performed for non-heated samples (20 °C). The TG, DTG, and DTA curves were analysed to investigate the effects related to the dehydration and the decomposition of hydration and carbonation products. Compared to mortar samples without fibres, the results showed that the presence of polypropylene fibres contributes to an increase in the thermal stability of the samples. It has been proven that the impact of the type and amount of PP fibres in the tested range (1.8 kg/m(3) vs. 3.6 kg/m(3)) on the thermal stability of specimens of tested cement composites was found not to be significantly visible. Next, extensive research was performed on the impact of fire environmental exposure on the variability in the strength parameters of the mortars. Tensile strength tests were conducted based on the standards specified by the Polish Committee for Standardization. The research material consisted of high-strength, fine-grained building mortars, modified by an original method with polypropylene fibres at concentration of 1.8 kg/m(3), 3.0 kg/m(3), and 3.6 kg/m(3). For reference, ordinary mortars without fibres were used, as well. Tensile strength was evaluated for mortar samples, which were exposed to temperatures of 100 °C, 200 °C, 300 °C, 400 °C, 500 °C, and 600 °C, respectively. Special attention was paid to the thermal behaviour of cement mortars reinforced with polypropylene (PP) fibres, subjected to high temperatures. Based on the obtained test results, a detailed statistical analysis was developed, along with comprehensive temperature-parameter relationships, which could enable an approximate post-failure assessment of the mortar's condition. The main outcomes of this paper include optimal fibre dosage, which is 3.6 kg/m(3), identified optimal fibre type, namely F fibre, as well as plateau in tensile strength for temperatures between 200 °C and 400 °C for fibre-reinforced samples.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。