Highly Sensitive Detection of Benzoyl Peroxide Based on Organoboron Fluorescent Conjugated Polymers

基于有机硼荧光共轭聚合物的高灵敏检测过氧化苯甲酰

阅读:5
作者:Mingyuan Yin, Caiyun Zhang, Jing Li, Haijie Li, Qiliang Deng, Shuo Wang

Abstract

The method capable of rapid and sensitive detection of benzoyl peroxide (BPO) is necessary and receiving increasing attention. In consideration of the vast signal amplification of fluorescent conjugated polymers (FCPs) for high sensitivity detection and the potential applications of boron-containing materials in the emerging sensing fields, the organoboron FCPs, poly (3-aminophenyl boronic acid) (PABA) is directly synthesized via free-radical polymerization reaction by using the commercially available 3-aminophenyl boronic acid (ABA) as the functional monomer and ammonium persulfate as the initiator. PABA is employed as a fluorescence sensor for sensing of trace BPO based on the formation of charge-transfer complexes between PABA and BPO. The fluorescence emission intensity of PABA demonstrates a negative correlation with the concentration of BPO. And a linear range of 8.26 × 10-9 M-8.26 × 10-4 M and a limit of detection of 1.06 × 10-9 M as well as a good recovery (86.25%-111.38%) of BPO in spiked real samples (wheat flour and antimicrobial agent) are obtained. The proposed sensor provides a promising prospective candidate for the rapid detection and surveillance of BPO.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。