Whole-cell electric sensor for determination of sodium dodecyl sulfate

用于测定十二烷基硫酸钠的全细胞电传感器

阅读:5
作者:Natalya S Velichko, Olga I Guliy, Matvei V Kanevsky, Maria A Kupryashina, Yulia P Fedonenko

Abstract

Linear alkyl sulfates are a major class of surfactants that have large-scale industrial application and thus wide environmental release. These organic pollutants threaten aquatic environments and other environmental compartments. We show the promise of the use of a whole-cell electric sensor in the analysis of low or residual concentrations of sodium dodecyl sulfate (SDS) in aqueous solutions. On the basis of bioinformatic analysis and alkylsulfatase activity determinations, we chose the gram-negative bacterium Herbaspirillum lusitanum, strain P6-12, as the sensing element. Strain P6-12 could utilize 0.01-400 mg/L of SDS as a growth substrate. The electric polarizability of cell suspensions changed at all frequencies used (50-3000 kHz). The determination limit of 0.01 mg/L is much lower than the official requirements for the content of SDS in potable and process water (0.5 and 1.0 mg/L, respectively), and the analysis takes about 1-5 min. The promise of H. lusitanum P6-12 for use in the remediation of SDS-polluted soils is discussed.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。