Integrated pulmonary index during procedural sedation and analgesia: A cluster-randomized trial

手术镇静和镇痛期间的综合肺功能指数:一项整群随机试验

阅读:2

Abstract

AIM: To evaluate the effectiveness of utilizing the integrated pulmonary index for capnography implementation during sedation administered by nurses. DESIGN: Cluster-randomized trial. METHODS: Participants were enrolled from the interventional radiology department at an academic hospital in Canada. Nurses were randomized to either enable or disable the Integrated Pulmonary Index feature of the capnography monitor. Procedures were observed by a research assistant to collect information about alarm performance characteristics. The primary outcome was the number of seconds in an alert condition state without an intervention being applied. RESULTS: The number of seconds in an alarm state without intervention was higher in the group that enabled the integrated pulmonary index compared to the group that disabled this feature, but this difference did not reach statistical significance. Likewise, the difference between groups for the total alarm duration, total number of alarms and the total number of appropriate alarms was not statistically significant. The number of inappropriate alarms was higher in the group that enabled the Integrated Pulmonary Index, but this estimate was highly imprecise. There was no difference in the odds of an adverse event (measured by the Tracking and Reporting Outcomes of Procedural Sedation tool) occurring between groups. Desaturation events were uncommon and brief in both groups but the area under the SpO(2) 90% desaturation curve scores were lower for the group that enabled the integrated pulmonary index. CONCLUSION: Enabling the integrated pulmonary index during nurse-administered procedural sedation did not reduce nurses' response times to alarms. Therefore, integrating multiple physiological parameters related to respiratory assessment into a single index did not lower the threshold for intervention by nurses. IMPLICATIONS FOR THE PROFESSION AND/OR PATIENT CARE: The time it takes to respond to capnography monitor alarms will not be reduced if the integrated pulmonary Iindex feature of capnography monitors is enabled during nurse-administered procedural sedation. IMPACT: Results do not support the routine enabling of the integrated pulmonary index when nurses use capnography to monitor patients during procedural sedation as a strategy to reduce the time it takes to initiate responses to alarms. REPORTING METHOD: CONSORT. PATIENT OR PUBLIC CONTRIBUTION: There was no patient or public contribution. TRIAL REGISTRATION: This study was prospectively registered at ClinicalTrials.gov (ID: NCT05068700).

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。