Development and evaluation of indirect enzyme-linked immunosorbent assay using recombinant dense granule antigen 7 protein for the detection of Toxoplasma gondii infection in cats in Thailand

开发并评估使用重组致密颗粒抗原 7 蛋白的间接酶联免疫吸附试验来检测泰国猫弓形虫感染

阅读:13
作者:Eukote Suwan, Piangjai Chalermwong, Rucksak Rucksaken, Metita Sussadee, Sarawan Kaewmongkol, Ruenruetai Udonsom, Sathaporn Jittapalapong, Bandid Mangkit

Aim

Toxoplasma gondii is recognized as a zoonosis causing toxoplasmosis in animals globally. Cat is a definitive host of T. gondii and sheds oocyst through feces, which can infect human beings and animals through contaminated food ingestion. A precise diagnostic test is essential to prevent T. gondii infection in both humans and animals. This study aimed to develop and evaluate the pETite-dense granule antigen 7(GRA7)-based indirect enzyme-linked immunosorbent assay (ELISA) to detect T. gondii infection in cats. Materials and

Conclusion

In this study, the pETite™ vector, N-terminal 6xHis SUMO fusion tag, was used to improve the solubility and expression level of GRA7. The recombinant pETite-GRA7 showed enhanced protein solubility and purification without special condition requirements. This pETite-GRA7-based indirect ELISA showed high concordant results and substantial agreement with IFAT. ELISA revealed an acceptable sensitivity and specificity. These initial data obtained from cats' sera demonstrated that pETite-GRA7-based indirect ELISA could be a useful method for local serological diagnosis of T. gondii infection in cats in Thailand.

Methods

T. gondii-GRA7 was cloned and expressed in the Expresso®small ubiquitin-related modifier (SUMO) T7 Cloning and Expression System. The recombinant pETite-GRA7 was purified using HisTrap affinity chromatography and confirmed using Western blot analysis. The recombinant protein was used to develop and evaluate the indirect ELISA for T. gondii infection detection. In total, 200 cat sera were tested using pETite-GRA7-based indirect ELISA and indirect fluorescent antibody test (IFAT). The statistical analysis based on Kappa value, sensitivity, specificity, positive predictive value, negative predictive value, χ 2 test, and receiver operating characteristic (ROC) curve was used to evaluate the performance of the test.

Results

A 606 bp GRA7 polymerase chain reaction (PCR) product was obtained from T. gondii RH strain genomic DNA. The gene was cloned into the pETite™ vector and transformed to HI-Control Escherichia coli BL21 (DE3) for protein expression. Approximately 35 kDa of recombinant pETite-GRA7 was observed and Western blot analysis showed positive bands against anti-6-His antibody and positive-T. gondii cat serum. A sample of 0.5 μg/mL of pETite-GRA7 was subjected to indirect ELISA to detect T. gondii infection in the cat sera. The results showed sensitivity and specificity of pETite-GRA7-based indirect ELISA at 72% and 96%, respectively. An acceptable diagnostic performance was characterized by high concordant results (94%) and substantial agreement (Kappa value=0.65) with IFAT. The seroprevalence levels of ELISA and IFAT were 10% and 9%, respectively, and were not significantly (p>0.05) different. The expected performance of ELISA at different cutoff points using the ROC curve analysis revealed 89% sensitivity and 92% specificity at the cutoff value of 0.146, with a high overall assay accuracy (area under the curve=0.94).

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。