Validation of the Thermo Scientific SureTect™ Campylobacter jejuni, C. coli, and C. lari PCR Kit for the Detection of Campylobacter jejuni, C. coli, and C. lari in Raw Poultry and Ready-to-Cook Poultry Products: AOAC Performance Tested MethodSM 012101

验证 Thermo Scientific SureTect™ 空肠弯曲菌、大肠弯曲菌和红嘴鸥弯曲菌 PCR 试剂盒对生禽肉和即食禽肉产品中空肠弯曲菌、大肠弯曲菌和红嘴鸥弯曲菌的检测能力:AOAC 性能测试方法 SM 012101

阅读:5
作者:Nikki Faulds, Katharine Evans, Jessica Williams, David Crabtree, Annette Hughes, Patrick Stephenson, Dean Leak, Daniele Sohier, Jukka-Pekka Palomäki, Benjamin Bastin, M Joseph Benzinger, James Agin

Background

The Thermo Scientific SureTect™ Campylobacter jejuni, C. coli, and C. lari PCR Kit is a real-time PCR assay for the detection and differentiation of C. jejuni, C. coli, and C. lari from raw poultry, ready-to-cook poultry products, and environmental samples.

Conclusion

The data presented support the product claims that the Thermo Scientific SureTect Campylobacter jejuni, C. coli, and C. lari PCR assay is suitable for the detection and differentiation of C. jejuni, C. coli, and C. lari from raw poultry, ready-to-cook poultry products, and environmental samples. Highlights: Presumptive results can be obtained in as little as 23 h. Microaerophilic incubators are not required for enrichment.

Methods

Inclusivity/exclusivity, matrix studies, product consistency and stability, and robustness testing were conducted to assess the method's performance. In the matrix studies, the method was validated against United States and international reference methods for Campylobacter detection.

Objective

The Thermo Scientific SureTect Campylobacter jejuni, C. coli, and C. lari PCR Kit was evaluated for AOAC®Performance Tested MethodsSM certification.

Results

There were no statistically significant differences found in the matrix studies between the candidate and reference methods when analyzed by probability of detection. All 52 inclusivity strains and none of the 51 exclusivity strains tested were detected by the assay. Robustness testing demonstrated that the assay gave reliable performance with specific method deviations outside of the recommended parameters, and the real-time stability testing demonstrated that there were no statistically significant differences between kit lots, validating the stated shelf life of the kit.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。