Conclusions
Use of the 3DP scaffold coated with MSCs seeded in fibrin resulted in successful restoration of the shape and histology of the cervical oesophagus without any graft rejection; thus, this is a promising material for use as an artificial oesophagus.
Methods
MSCs from rabbit bone marrow were cultured, and a 3DP polycaprolactone (PCL) scaffold was coated with the MSCs seeded in fibrin. The fibrin/MSC-coated 3DP PCL scaffold was implanted on a 5 × 10 mm artificial oesophageal defect in three rabbits (3DP/MSC group) and 3DP PCL-only scaffolds were implanted in three rabbits (3DP-only group). Three weeks post-procedure, the implanted sites were evaluated radiologically and histologically.
Results
None of the rabbits showed any infection, stenosis or granulation on computed tomography. In the 3DP/MSC group, the replaced scaffolds were completely covered with regenerating mucosal epithelium and smooth muscle cells as determined by haematoxylin and eosin and Desmin staining. However, mucosal epithelium and smooth muscle cell regeneration was not evident in the 3DP-only group. Conclusions: Use of the 3DP scaffold coated with MSCs seeded in fibrin resulted in successful restoration of the shape and histology of the cervical oesophagus without any graft rejection; thus, this is a promising material for use as an artificial oesophagus.