Advancing free-breathing liver diffusion-weighted imaging with Propeller-EPI: Improved image quality and ADC repeatability

利用Propeller-EPI技术推进自由呼吸肝脏弥散加权成像:提高图像质量和ADC重复性

阅读:2

Abstract

BACKGROUND: Liver diffusion-weighted imaging (DWI) with apparent diffusion coefficient (ADC) measurement has proven valuable in diagnosing liver diseases. In certain patient populations, a free-breathing (FB) liver DWI approach is desirable to improve patient comfort and broaden clinical applicability. However, maintaining high image quality under FB conditions and achieving satisfactory ADC repeatability can be challenging when using routine diffusion-weighted single-shot echo-planar imaging (DW-ss-EPI). PURPOSE: This study aimed to develop an advanced FB liver DWI technique based on diffusion-weighted Propeller echo-planar imaging (DW-Propeller-EPI) to achieve motion compensation, and to prospectively evaluate its performance in terms of image quality and ADC repeatability compared to standard DW-ss-EPI. METHODS: A DW-Propeller-EPI pulse sequence and reconstruction pipeline was developed on a 1.5T MRI system. The pipeline incorporated a reference-free Nyquist ghost correction method and motion compensation using correlation weighting during data reconstruction. For in vivo evaluation, participants prospectively underwent two repeated liver DWI scans using four techniques: three routine DW-ss-EPI sequences with different breathing controls (breath-holding, BH; respiratory-triggering, RT; and FB), and one FB DW-Propeller-EPI sequence. The raw data from the FB DW-Propeller-EPI scans were processed offline with the developed motion-compensated reconstruction. Two radiologists independently rated the image quality on a 5-point scale across five aspects (signal homogeneities in the left lobe, geometric fidelity, liver edge sharpness, vessel clarity, and overall image quality). Mean scores were compared among the four techniques using the Friedman test. The repeatability of ADC measurements was evaluated with Bland-Altman analysis, and differences in ADC values between liver lobes and techniques were analyzed using two-way repeated measures ANOVA. RESULTS: 35 participants were enrolled, with twenty completing repeated scans. FB DW-Propeller-EPI demonstrated significantly higher ratings than the three routine DW-ss-EPI sequences across all aspects (all P < 0.001), with good interobserver agreements (ICC ranging from 0.80-0.88). The mean geometric fidelity score of FB DW-Propeller-EPI was rated the highest (4.86 ± 0.33). FB DW-Propeller-EPI also exhibited superior ADC repeatability in both the left and right liver lobes (LOA: 0.212 × 10(-3) mm(2)/s versus 0.255 × 10(-3) mm(2)/s). ADC measurements were comparable between FB DW-Propeller-EPI and both RT or FB DW-ss-EPI techniques. CONCLUSIONS: The proposed FB DW-Propeller-EPI technique enables high-quality FB liver DWI with satisfactory ADC repeatability, outperforming conventional DW-ss-EPI in image quality and ADC repeatability. This advancement addresses the limitations of routine DW-ss-EPI in FB scenarios, offering a promising solution for clinical applications in challenging population.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。