Deep learning-based harmonization of trabecular bone microstructures between high- and low-resolution CT imaging

基于深度学习的高分辨率和低分辨率CT成像中小梁骨微结构的协调

阅读:1

Abstract

BACKGROUND: Osteoporosis is a bone disease related to increased bone loss and fracture-risk. The variability in bone strength is partially explained by bone mineral density (BMD), and the remainder is contributed by bone microstructure. Recently, clinical CT has emerged as a viable option for in vivo bone microstructural imaging. Wide variations in spatial-resolution and other imaging features among different CT scanners add inconsistency to derived bone microstructural metrics, urging the need for harmonization of image data from different scanners. PURPOSE: This paper presents a new deep learning (DL) method for the harmonization of bone microstructural images derived from low- and high-resolution CT scanners and evaluates the method's performance at the levels of image data as well as derived microstructural metrics. METHODS: We generalized a three-dimensional (3D) version of GAN-CIRCLE that applies two generative adversarial networks (GANs) constrained by the identical, residual, and cycle learning ensemble (CIRCLE). Two GAN modules simultaneously learn to map low-resolution CT (LRCT) to high-resolution CT (HRCT) and vice versa. Twenty volunteers were recruited. LRCT and HRCT scans of the distal tibia of their left legs were acquired. Five-hundred pairs of LRCT and HRCT image blocks of 64 × 64 × 64 voxels were sampled for each of the twelve volunteers and used for training in supervised as well as unsupervised setups. LRCT and HRCT images of the remaining eight volunteers were used for evaluation. LRCT blocks were sampled at 32 voxel intervals in each coordinate direction and predicted HRCT blocks were stitched to generate a predicted HRCT image. RESULTS: Mean ± standard deviation of structural similarity (SSIM) values between predicted and true HRCT using both 3DGAN-CIRCLE-based supervised (0.84 ± 0.03) and unsupervised (0.83 ± 0.04) methods were significantly (p < 0.001) higher than the mean SSIM value between LRCT and true HRCT (0.75 ± 0.03). All Tb measures derived from predicted HRCT by the supervised 3DGAN-CIRCLE showed higher agreement (CCC   ∈  [0.956 0.991]) with the reference values from true HRCT as compared to LRCT-derived values (CCC   ∈ [0.732 0.989]). For all Tb measures, except Tb plate-width (CCC = 0.866), the unsupervised 3DGAN-CIRCLE showed high agreement (CCC   ∈  [0.920 0.964]) with the true HRCT-derived reference measures. Moreover, Bland-Altman plots showed that supervised 3DGAN-CIRCLE predicted HRCT reduces bias and variability in residual values of different Tb measures as compared to LRCT and unsupervised 3DGAN-CIRCLE predicted HRCT. The supervised 3DGAN-CIRCLE method produced significantly improved performance (p < 0.001) for all Tb measures as compared to the two DL-based supervised methods available in the literature. CONCLUSIONS: 3DGAN-CIRCLE, trained in either unsupervised or supervised fashion, generates HRCT images with high structural similarity to the reference true HRCT images. The supervised 3DGAN-CIRCLE improves agreements of computed Tb microstructural measures with their reference values and outperforms the unsupervised 3DGAN-CIRCLE. 3DGAN-CIRCLE offers a viable DL solution to retrospectively improve image resolution, which may aid in data harmonization in multi-site longitudinal studies where scanner mismatch is unavoidable.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。