Development and Quality Assurance of Multileaf Collimator (MLC) Auto-Feathering Junctions for Multi-Isocenter Supine Volumetric Modulated Arc Therapy (VMAT) Craniospinal Axis Irradiation on Halcyon

Halcyon平台上用于多中心仰卧位容积调强弧形治疗(VMAT)颅脊髓轴照射的多叶准直器(MLC)自动羽化连接点的开发和质量保证

阅读:1

Abstract

Currently, there is a lack of methods and tools that efficiently evaluate the auto-feathering junctions created by multileaf collimator (MLCs) for supine volumetric modulated arc therapy (VMAT) craniospinal irradiation (CSI) plans. We have investigated the feasibility of stitching together multi-isocenter fluence maps to then analyze the feathered junctions for patient-specific quality assurance (QA). Furthermore, we investigated the capability of Halcyon for the treatment of CSI patients. Three patients, who previously underwent VMAT CSI treatment on TrueBeam (6-MV flattening filter-free (FFF)) for 36 Gy in 20 fractions were replanned for Halcyon. A multi-isocenter approach with only translational superior-inferior shifts was used for both platforms. Each isocenter consists of two full arcs with anterior avoidance sectors, ±5° collimator rotations between arcs, and 5-8 cm of overlapping MLC auto-feathering junctions. All plans were QA'd via electronic portal imaging device (EPID) portal dosimetry and analyzed with a gamma criteria of 3%/3 mm. A variety of plan quality metrics were analyzed to evaluate dose distributions to the target, doses to organs at risk (OARs), and integral dose to the patient. A MATLAB script was developed to stitch the calculated and measured fluence maps in order to perform patient-specific QA for the composite fluence. The Halcyon plans provided highly conformal and homogenous dose distributions to the entire CSI target, superior to the clinical TrueBeam plans, while sparing critical organs with significantly lower values of V10Gy and V18Gy by up to 2% and 2.5%, respectively. Qualitative depictions of vertical dose profiles from the stitched DICOM of the entire CSI target for both planned and delivered fluence maps demonstrated equivalency, with slightly lower average pass rates with Halcyon (97%) compared to TrueBeam (99.9%). This approach to stitch multiple measured versus calculated EPID fluence maps has shown to be a feasible and accurate method and will be helpful for comprehensive VMAT CSI QA on both platforms. Further implementation of this script will be used in examining dosimetric impacts of daily patient positioning errors at MLC auto-feathering junctions.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。