Quantification of translocator protein (18 kDa) in the human brain with PET and a novel radioligand, (18)F-PBR06

利用PET和新型放射性配体(18)F-PBR06对人脑中的转运蛋白(18 kDa)进行定量分析

阅读:1

Abstract

Translocator protein (TSPO) (18 kDa), formerly called the peripheral benzodiazepine receptor, is upregulated on activated microglia and macrophages and is, thus, a biomarker of inflammation. We previously reported that an (11)C-labeled aryloxyanilide (half-life, 20 min) was able to quantify TSPOs in the healthy human brain. Because many PET centers would benefit from a longer-lived (18)F-labeled radioligand (half-life, 110 min), the objective of this study was to evaluate the ability of a closely related aryloxyanilide ((18)F-N-fluoroacetyl-N-(2,5-dimethoxybenzyl)-2-phenoxyaniline [(18)F-PBR06]) to quantify TSPOs in the healthy human brain. METHODS: A total of 9 human subjects were injected with (18)F-PBR06 (approximately 185 MBq) and scanned for 5 h, with rest periods outside the camera. The concentrations of (18)F-PBR06, separated from radiometabolites, were measured in arterial plasma. RESULTS: Modeling of regional brain and plasma data showed that a 2-tissue-compartment model was superior to a 1-tissue-compartment model. Even if data for all time points were used for the fitting, concentrations of brain activity measured with PET were consistently greater than the modeled values at late (280-300 min) but not at early time points. The greater values may have been caused by the slow accumulation of radiometabolites in the brain. To determine an adequate time for more accurate measurement of distribution volume (V(T)), which is the summation of receptor binding and nondisplaceable activity, we investigated which scan duration would be associated with maximal or near-maximal identifiability. We found that a scan of 120 min provided the best identifiability of V(T) (approximately 2%). The images showed no significant defluorination. CONCLUSION: (18)F-PBR06 can quantify TSPOs in the healthy human brain using 120 min of image acquisition and concurrent measurements of radioligand in plasma. Although brain activity is likely contaminated with radiometabolites, the percentage contamination is thought to be small (<10%), because values of distribution volume are stable during 60-120 min and vary by less than 10%. (18)F-PBR06 is a longer-lived and promising alternative to (11)C-labeled radioligands to measure TSPOs as a biomarker of inflammation in the brain.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。