Single-photon Emission Computed Tomography-Computed Tomography Using (99m)Tc-labeled Leukocytes for Evaluating Infection Associated with a Cranial Implant in a Rhesus Macaque (Macaca mulatta)

利用(99m)Tc标记的白细胞进行单光子发射计算机断层扫描-计算机断层扫描,以评估恒河猴(Macaca mulatta)颅内植入物相关的感染

阅读:1

Abstract

An adult male rhesus macaque (Macaca mulatta) that was enrolled in a study evaluating cognition and memory presented with suppurative exudate along the margins of a long-standing cranial implant that included a stainless-steel head post, plastic left-sided recording cylinder, and acrylic over a previously placed right-sided recording cylinder. Both cylinders were located at the level of the prefrontal cortex. After treatment comprising systemic antibiotics and daily cleaning with povidone-iodine for several months, the macaque underwent single-photon emission computed tomography-computed tomography (SPECT-CT) in which his neutrophils were labeled with (99m)Tc-hexamethylpropylene amine oxime ( 99m Tc-HMPAO) to evalu- ate for active infection below the implant. Soft tissue inflammation and osteomyelitis were found at the site of the previous right-sided recording cylinder. Cephalosporin and tetracycline antibiotics were administered for 12 wk. Follow-up SPECT-CT imaging was then performed to evaluate response to medical treatment. Results indicated no change in the degrees of soft tissue inflammation and osteomyelitis associated with the right-sided recording cylinder site. SPECT-CT imaging was used to guide the surgical removal of the implant and debridement of the infected tissue. On removal of the entire cranial implant, the osteomyelitis and soft tissue inflammation observed on the pre- and posttreatment SPECT-CT scans were confirmed. In addition, a large cavitary defect through the calvarium with suppurative exudate was discovered below the base of the head post. Infection in this defect was not apparent on SPECT; however, the bony defect was confirmed on reevaluation of the CT images. We concluded that the infection in this defect was silent on SPECT due to the limited vascularization of the sur-rounding bone and the chronicity of the infection. This case study is the first to describe the use of SPECT-CT for evaluating soft tissue inflammation and osteomyelitis beneath a cranial implant in a NHP.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。