Between-patient and within-patient (site-to-site) variability in estrogen receptor binding, measured in vivo by 18F-fluoroestradiol PET

通过 18F-氟雌二醇 PET 在体内测量雌激素受体结合的患者间和患者内(部位间)变异性

阅读:1

Abstract

Heterogeneity of estrogen receptor (ER) expression may be an important predictor of breast cancer therapeutic response. (18)F-fluoroestradiol PET produces in vivo quantitative measurements of regional estrogen binding in breast cancer tumors. We describe within-patient (site-to-site) and between-patient heterogeneity of lesions in patients scheduled to receive endocrine therapy. METHODS: In 91 patients with a prior ER-positive biopsy, 505 lesions were analyzed for both (18)F-fluoroestradiol and (18)F-FDG uptake and the (18)F-fluoroestradiol/(18)F-FDG uptake ratio. Standardized uptake values (SUVs) were recorded for up to 16 lesions per patient, of 1.5 cm or more and visible on (18)F-FDG PET or conventional staging. Linear mixed-effects regression models examined associations between PET parameters and patient or lesion characteristics and estimated variance components. A reader study of SUV measurements for 9 scans further examined sources of within-patient variability. RESULTS: Average (18)F-fluoroestradiol uptake and (18)F-fluoroestradiol/(18)F-FDG ratio varied greatly across these patients, despite a history of ER-positive disease: about 37% had low or absent (18)F-fluoroestradiol uptake even with marked (18)F-FDG uptake. (18)F-fluoroestradiol SUV and (18)F-fluoroestradiol/(18)F-FDG ratio measurements within patients with multiple lesions were clustered around the patient's average value in most cases. Summarizing these findings, the intraclass correlation coefficient (proportion of total variation that is between-patient) was 0.60 (95% confidence interval, 0.50-0.69) for (18)F-fluoroestradiol SUV and 0.65 (95% confidence interval, 0.56-0.73) for the (18)F-fluoroestradiol/(18)F-FDG ratio. Some within-patient variation in PET measures (22%-44%) was attributable to interobserver variability as measured by the reader study. A subset of patients had mixed uptake, with widely disparate (18)F-fluoroestradiol SUV or (18)F-fluoroestradiol/(18)F-FDG ratio for lesions in the same scan. CONCLUSION: (18)F-fluoroestradiol uptake and the (18)F-fluoroestradiol/(18)F-FDG ratio varied greatly between patients but were usually consistent across lesions in the same scan. The average (18)F-fluoroestradiol SUV and (18)F-fluoroestradiol/(18)F-FDG ratio for a limited sample of lesions appear to provide a reasonable summary of synchronous ER expression for most patients. However, imaging the entire disease burden remains important to identify the subset of patients with mixed uptake, who may be at a critical point in their disease evolution.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。