Addition of dNTPs can improve the detection sensitivity of catalytic hairpin assembly

添加 dNTP 可以提高催化发夹组装的检测灵敏度

阅读:5
作者:Mingyuan Zou, Meiling Zhou, Shuo Ma, Chen Zhang, Feng Xiao, Huina Wu, Abudushalamu GuliNaizhaer, Yuming Yao, Yaya Chen, Shijie Cai, Xiaobo Fan, Fengfeng Zhao, Guoqiu Wu

Abstract

Ever since the catalytic hairpin assembly (CHA) circuit has been highlighted as a powerful nucleic acid detection tool, nucleic acid detection methods based on CHA have been widely studied. However, the detection sensitivity of CHA-based methods is insufficient. The relatively high background signals resulting from the spontaneous reaction between the two hairpin probes is one of the major reasons for limiting the sensitivity of CHA. In this study, we established that the addition of deoxynucleotide triphosphates (dNTPs) to the reaction system can significantly reduce the background leakage of CHA. The dNTPs-CHA, coupled with a fluorescence lateral flow assay strip, is used for the rapid and highly sensitive detection of miRNA. It is capable of reliably detecting miRNA in serum samples down to a limit of 100 aM, which is an improvement in the lower detection limit by nearly five orders of magnitude compared to that of the pure CHA.

特别声明

1、本文转载旨在传播信息,不代表本网站观点,亦不对其内容的真实性承担责任。

2、其他媒体、网站或个人若从本网站转载使用,必须保留本网站注明的“来源”,并自行承担包括版权在内的相关法律责任。

3、如作者不希望本文被转载,或需洽谈转载稿费等事宜,请及时与本网站联系。

4、此外,如需投稿,也可通过邮箱info@biocloudy.com与我们取得联系。