Abstract
An improved sample preparation procedure for trace-levels of lanthanides in uranium-bearing samples was developed. The method involves a simple co-precipitation using Fe(III) carrier in ammonium carbonate medium to remove the uranium matrix. The procedure is an effective initial pre-concentration step for the subsequent extraction chromatographic separations. The applicability of the method was demonstrated by the measurement of REE pattern and 143Nd/144Nd isotope ratio in uranium ore concentrate samples.