Spatial frequency domain imaging technology based on Fourier single-pixel imaging

基于傅里叶单像素成像的空间频率域成像技术

阅读:1

Abstract

SIGNIFICANCE: Optical properties (absorption coefficient and scattering coefficient) of tissue are the most critical parameters for disease diagnosis-based optical method. In recent years, researchers proposed spatial frequency domain imaging (SFDI) to quantitatively map tissue optical properties in a broad field of contactless imaging. To solve the limitations in wavebands unsuitable for silicon-based sensor technology, a compressed sensing (CS) algorithm is used to reproduce the original signal by a single-pixel detectors. Currently, the existing single-pixel SFDI method mainly uses a random sampling policy to extract and recover signals in the acquisition stage. However, these methods are memory-hungry and time-consuming, and they cannot generate discernible results under low sampling rate. Explorations on high performance and efficiency single-pixel SFDI are of great significance for clinical application. AIM: Fourier single-pixel imaging can reconstruct signals with less time and space costs and has fewer reconstruction errors. We focus on an SFDI algorithm based on Fourier single-pixel imaging and propose our Fourier single-pixel image-based spatial frequency domain imaging method (FSI-SFDI). APPROACH: First, we use Fourier single-pixel imaging algorithm to collect and compress signals and SFDI algorithm to generate optical parameters. Given the basis that the main energy of general image signals is concentrated in the range of low frequency of Fourier frequency domain, our FSI-SFDI uses a circular-sampling scheme to sample data points in the low-frequency region. Then, we reconstruct the image details from these points by optimization-based inverse-FFT method. RESULTS: Our algorithm is tested on simulated data. Results show that the root mean square error (RMSE) of optical parameters is lower than 5% when the data reduction is 92%, and it can generate discernible optical parameter image with low sampling rate. We can observe that our FSI-SFDI primarily recovers the optical properties while keeping the RMSE under the upper bound of 4.5% when we use an image with 512  ×  512 resolution as the example for calculation and analysis. Not only that but also our algorithm consumes less space and time for an image with 256  ×  256 resolution, the signal reconstruction takes only 1.65 ms, and requires less RAM memory. Compared to CS-SFDI method, our FSI-SFDI can reduce the required number of measurements through optimizing algorithm. CONCLUSIONS: Moreover, FSI-SFDI is capable of recovering high-quality resolvable images with lower sampling rate, higher-resolution images with less memory and time consumed than previous CS-SFDI method, which is very promising for clinical data collection and medical analysis.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。