Safety and efficacy of biolimus-eluting stent with biodegradable polymer: insights from EINSTEIN (Evaluation of Next-generation drug-eluting STEnt IN patients with coronary artery disease) Registry

采用可生物降解聚合物的生物溶菌酶洗脱支架的安全性和有效性:来自 EINSTEIN(评估下一代药物洗脱支架在冠状动脉疾病患者中的应用)注册研究的启示

阅读:1

Abstract

OBJECTIVE: To evaluate the incidence of major adverse cardiac events (cardiac death, or acute myocardial infarct, or target vessel revascularization) at one year in "real world" patients. METHODS: The EINSTEIN registry is an observational, prospective, single center study that consecutively included 103 patients (152 lesions) treated with the BiomatrixTM stent, a biolimus A9-eluting stent with biodegradable polymer. RESULTS: The mean age was 65.0±12.4 years; male gender represented 83.5% of the patients; and 37.9% of them were diabetic. At one-year, major adverse cardiac events occurred in 11.7% of the patients, including 2.9% of cardiac death, 4.9% of with non ST- segment elevation acute myocardial infarction, and 3.9% of target vessel revascularization. Stent thrombosis occurred in only 1% (1 patient) at one-yearfollow-up. CONCLUSION: The present Registry suggests that new generation biolimus A9 drug-eluting stents are safe and effective in a "real world", all-comers patients, showing low rates of major cardiac adverse events on long-term follow-up.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。