Semi-automatic quantitative analysis of the pelvic bony structures on apparent diffusion coefficient maps based on deep learning: establishment of reference ranges

基于深度学习的表观扩散系数图上骨盆骨骼结构的半自动定量分析:参考范围的建立

阅读:1

Abstract

BACKGROUND: Apparent diffusion coefficient (ADC) maps provide quantitative information on both normal and abnormal tissues. However, it is difficult to distinguish between these tissues unless consistent and precise ADC values can be obtained from normal tissues. For this study we developed a deep learning-based convolutional neural network (CNN) for pelvic bony structure segmentation and established the reference ranges of ADC parameters for normal pelvic bony structures. METHODS: We retrospectively enrolled 767 prostate cancer (PCa) patients for quantitative ADC analyses of normal pelvic bony structures. A subset of 288 patients who did not receive treatment for PCa (S1) were used to develop a CNN model for the segmentation of 8 pelvic bony structures (lumbar vertebra, sacrococcyx, ilium, acetabulum, femoral head, femoral neck, ischium, and pubis). The proposed CNN was used for the automated segmentation of these pelvic bony structures from a subset of 405 patients who did not receive treatment (S2) and 74 patients who received treatment [radiotherapy (S3) or endocrine therapy (S4)]. The 95% confidence interval (CI) was used to establish reference ranges for the ADC values from the normal pelvic bony structures of S1 and S2. RESULTS: The Dice scores (Sørensen-Dice coefficient) for the CNN segmentation of the 8 pelvic bones on the ADC maps ranged from 0.90±0.02 (ilium) to 0.95±0.03 (femoral head) in the S1 testing set. In the S2 data set, the Dice scores showed no significant difference among the different scanners (P>0.05), and no significant differences were found among the S2, S3, and S4 data sets. The correlation analysis revealed that the b value and field strength were significantly correlated with ADC values (all P<0.001), while age and treatment were not significant variables (all P>0.05). The ADC reference ranges (95% CI) were as follows: lumbar vertebra, 1.11 (0.90-1.54); sacrococcyx, 0.82 (0.61-1.15); ilium, 0.57 (0.45-0.62); acetabulum, 0.59 (0.40-0.69); femoral head, 0.46 (0.25-0.58); femoral neck, 0.43 (0.25-0.48); ischium, 0.45 (0.26-0.55); and pubis, 0.57 (0.45-0.65). CONCLUSIONS: This study preliminarily established reference ranges for the ADC values of normal pelvic bony structures. The image acquisition parameters had an influence on the ADC values.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。